High-speed serial interface (HSSI)
HSSI covers serial communication above 200 kbps. Used with the RS-232 DTE / DCE interface it gives a smaller footprint, higher throughput and lower power use.
Baud rate is given in bits per second. Older rates around 9,600 bps suit data where speed does not matter; modern rates are set in the serial register and go far beyond it. With a high-end serial modem, HSSI reaches roughly 300 to 900 kbps.
Many STX Technology products can be configured with several serial inputs, and a recent design has a module capable of 230,400 baud.
Standard and high-speed baud rates
| Standard rate | Time per bit | High-speed rate | Time per bit |
|---|---|---|---|
| 1,200 bps | 833.3 µs | 230,400 bps | 4.34 µs |
| 2,400 bps | 416.7 µs | 460,800 bps | 2.17 µs |
| 19,200 bps | 52.1 µs | 921,600 bps | 1.09 µs |
Time per bit = 1 ÷ baud rate.
Serial in a world of big data
Moving from parallel to high-speed serial buses raises performance while cutting size and power, and serial buses keep getting faster as data grows. Motion control and large industrial networks, such as EtherCAT over Ethernet, are driving it.
Ethernet is synchronous: the clock travels inside the data stream, so few wires are needed. RS-232 is asynchronous.
RS-232, RS-422 and RS-485
| RS-232 | RS-422 | RS-485 | |
|---|---|---|---|
| Line | Single-ended | Differential | Differential |
| Drivers | 1 | 1 | 32 |
| Receivers | 1 | 10 | 32 |
| Distance at 9,600 bps | 15 m | 1,200 m | 1,200 m |
| Driver output | 5 to 25 V | 2 to 6 V | 1.5 to 6 V |
| Driver load | under 3 kΩ | 100 Ω | 60 Ω |
| Topology | Point to point | Point to point | Multi-point |
Driver output depends on cable length and load.
CAN interface
CAN lets devices talk to each other without a host PC. It is a differential two-wire interface used mainly with microcontrollers in automotive, medical and networking equipment.